STARTUP
1. Before each startup, make sure
the power switch is in the OFF
position.
2. Place the air compressor on a
flat, level surface.
3. Release pressure from the
system. Drain moisture from the
air tank by slowly opening the air
tank drain valve by turning
counterclockwise. Once all the
moisture has drained out, close
the fitting securely.
NOTE: Air tank will not pressurize
while the drain valve is open.
4. Turn the pressure regulator
knob fully counterclockwise to
close airflow from air outlet port.
5. Attach air hose and
accessories.
WARNING: Too much air
pressure causes a hazardous
risk of bursting. Check the
manufacturers maximum
pressure rating for air tools and
accessories. The regulator
outlet pressure must never
exceed the maximum pressure
rating.
6. Before connecting the
compressor to the grounded
outlet, check for broken
components and accessories, and
check for damage to the hose.
7. Plug power cord direcly into a
properly grounded power source
of the correct voltage (see
grounding instructions).
8. Turn the compressor ON by
moving the switch to the
AUTO/ON position and allow tank
pressure to build. Once the air
pressure reaches the maximum
preset pressure (cut-out pressure)
it will automatically shut off.
9. Slowly turn the pressure
regulator knob clockwise to open
airflow from air outlet port until
desired output pressure is reached.
NOTE: The air compressor will
automatically restart once the
pressure in the air tank drops below
the minimum preset pressure (cut-
in pressure).
MAINTENANCE & CLEANING
WARNING: Disconnect air
compressor from the power
source and bleed off all air
pressure before attempting any
maintenance or repair.
SHUTDOWN & STORAGE
NOTE: NEVER stop the air
compressor by unplugging it from
the power outlet as this may result
in damage to the compressor.
1. Turn the switch to the OFF
position.
2. Disconnect the power cord from
the power outlet. Disconnect the
power cord from the power outlet by
grabbing the plug (not the cord).
Loop around electric cord holder for
storage.
3. Turn the pressure regulator knob
fully counterclockwise to close
airflow from air outlet port. Check
the outlet pressure gauge to ensure
that it reads 0 PSI.
4. Remove the air hose and any air
accessories.
5. Drain moisture from the air tank
by slowly opening the air tank drain
valve by turning counterclockwise.
Tilt tank to remove all moisture.
Once all the moisture has drained
out, close the fitting securely.
6. Allow the compressor to cool
down.
7. Wipe the air compressor clean
and store it in a clean, dry, and
non-freezing location.
WHEN PERFORMING ANY
MAINTENANCE OR SERVICE:
1. The air compressor must be
turned off.
2. Disconnect compressor from
the power source.
3. Open tank drain to bleed off
all air pressure before
attempting any maintenance or
repair.
4. Allow compressor to fully cool
before attempting any
maintenance or repair. Check
the air compressor frequently
for any visible problems and
follow maintenance procedures
each time the compressor is
used.
MAINTENANCE CHECKLIST
Daily:
o Drain accumulated liquid from
tank
o Check for unusual noise
and/or vibrations
o Check that all fasteners are
secure
o Wipe compressor clean
Weekly:
o Inspect and clean air filter